{"id":16819,"date":"2025-12-28T12:38:53","date_gmt":"2025-12-28T09:38:53","guid":{"rendered":"https:\/\/www.setaenerji.com.tr\/?page_id=16819"},"modified":"2025-12-28T12:40:54","modified_gmt":"2025-12-28T09:40:54","slug":"transformator-bakim-ve-onarimi","status":"publish","type":"page","link":"https:\/\/www.setaenerji.com.tr\/en\/transformator-bakim-ve-onarimi\/","title":{"rendered":"Transformer Maintenance and Repair"},"content":{"rendered":"<div data-elementor-type=\"wp-page\" data-elementor-id=\"16819\" class=\"elementor elementor-16819\">\n\t\t\t\t<div class=\"elementor-element elementor-element-2b61c4a9 e-con-full e-flex e-con e-parent\" data-id=\"2b61c4a9\" data-element_type=\"container\" data-core-v316-plus=\"true\">\n\t\t<div class=\"elementor-element elementor-element-2b10008f e-con-full e-flex e-con e-child\" data-id=\"2b10008f\" data-element_type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-1dd74bc0 color-scheme-inherit text-left elementor-widget elementor-widget-text-editor\" data-id=\"1dd74bc0\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t<style>\/*! elementor - v3.20.0 - 13-03-2024 *\/\n.elementor-widget-text-editor.elementor-drop-cap-view-stacked .elementor-drop-cap{background-color:#69727d;color:#fff}.elementor-widget-text-editor.elementor-drop-cap-view-framed .elementor-drop-cap{color:#69727d;border:3px solid;background-color:transparent}.elementor-widget-text-editor:not(.elementor-drop-cap-view-default) .elementor-drop-cap{margin-top:8px}.elementor-widget-text-editor:not(.elementor-drop-cap-view-default) .elementor-drop-cap-letter{width:1em;height:1em}.elementor-widget-text-editor .elementor-drop-cap{float:left;text-align:center;line-height:1;font-size:50px}.elementor-widget-text-editor .elementor-drop-cap-letter{display:inline-block}<\/style>\t\t\t\t<p>Transformer maintenance is critical to the efficient operation of energy systems. - TAP Transformer Power Transformer maintenance and repair as we offer professional service to our customers.<\/p><p>Our experienced technical team, the detection of faults, repairs and performing preventive maintenance activities quickly and effectively, if we&#039;re getting ahead of possible cuts.<\/p><h3>Transformer The Services We Provide<\/h3><h5>Onsite and workshop-type transformer Repair<\/h5><ul><li>Winding failures detection and repair<\/li><li>The body and renew the insulation transformer connection<\/li><li>Transformer connection settings and elimination of errors<\/li><li>Thermal protection and temperature sensor controls<\/li><\/ul><h5>Transformer oil maintenance and Treatment<\/h5><ul><li>Dielectric strength test<\/li><li>Water and gas analysis<\/li><li>Oil filtration and vacuum drying<\/li><li>Oil change and renewal<\/li><\/ul><h5>Periodic Maintenance Services\u00a0<\/h5><ul><li>Tap changer (OLTC) controls<\/li><li>Relay and control of thermal systems<\/li><li>Isolation tests (megger, hipot)<\/li><li>The firmness of control ports<\/li><li>Sealing tests<\/li><\/ul><h5>Testing and reporting<\/h5><ul><li>Measurement of insulation resistance<\/li><li>Winding ratio test (Turns Ratio)<\/li><li>Missing tests (idle and short circuit)<\/li><li>Capacitance and tan delta measurements<\/li><li>Detailed maintenance reports and situation assessment<\/li><\/ul><p>With our technical staff are experts in the field;<\/p><p><strong>Oily type power and distribution transformers,<\/strong><\/p><p><strong>Venue type, column type, and Transformers special project<\/strong>,<\/p><p><strong>36 kV to 36kV included) medium voltage transformers<\/strong><\/p><p>Comprehensive maintenance in accordance with national and international standards, testing, commissioning and technical support services we perform.<\/p>\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>","protected":false},"excerpt":{"rendered":"<p>Trafo bak\u0131m\u0131, enerji sistemlerinin verimli \u00e7al\u0131\u015fmas\u0131 i\u00e7in kritik \u00f6neme sahiptir. TAP POWER TRANSFORMER olarak trafo bak\u0131m\u0131 ve onar\u0131m\u0131 konusunda m\u00fc\u015fterilerimize<\/p>","protected":false},"author":1,"featured_media":0,"parent":0,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"footnotes":""},"class_list":["post-16819","page","type-page","status-publish","hentry"],"_links":{"self":[{"href":"https:\/\/www.setaenerji.com.tr\/en\/wp-json\/wp\/v2\/pages\/16819","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.setaenerji.com.tr\/en\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/www.setaenerji.com.tr\/en\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/www.setaenerji.com.tr\/en\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.setaenerji.com.tr\/en\/wp-json\/wp\/v2\/comments?post=16819"}],"version-history":[{"count":7,"href":"https:\/\/www.setaenerji.com.tr\/en\/wp-json\/wp\/v2\/pages\/16819\/revisions"}],"predecessor-version":[{"id":16827,"href":"https:\/\/www.setaenerji.com.tr\/en\/wp-json\/wp\/v2\/pages\/16819\/revisions\/16827"}],"wp:attachment":[{"href":"https:\/\/www.setaenerji.com.tr\/en\/wp-json\/wp\/v2\/media?parent=16819"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}